Government SI Register · VA · High impact
EPIQ Series Diagnostic Ultrasound System; Affiniti Series Diagnostic Ultrasound System
The Department of Veterans Affairs lists "EPIQ Series Diagnostic Ultrasound System; Affiniti Series Diagnostic Ultrasound System" in the 2025 federal inventory as a high impact SI use case at the deployed stage, in VHA: Veterans Health Administration. In the agency's words, the problem it is meant to solve: "The R-Trigger algorithm software feature on Philips EPIQ and Affiniti Ultrasound System is intended to support detection of R-wave peak (R-trigger) as an input to certain transthoracic echo (TTE) clinical applications, initially including AutoStrain LV, AutoEF, 2D Auto LV (collectively referred to as “AutoStrain”), and AutoMeasure applications. The R-trigger algorithm is expected to be implemented as workflow enhance..." Every field below is quoted as filed.
The record, as filed
Every field the agency reported
- Bureau or component
- VHA: Veterans Health Administration
- Stage
- Deployed
- High impact status
- High-impact
- Topic area
- Health and Medical
- Technology type
- Computer Vision
- Problem it is meant to solve
- The R-Trigger algorithm software feature on Philips EPIQ and Affiniti Ultrasound System is intended to support detection of R-wave peak (R-trigger) as an input to certain transthoracic echo (TTE) clinical applications, initially including AutoStrain LV, AutoEF, 2D Auto LV (collectively referred to as “AutoStrain”), and AutoMeasure applications. The R-trigger algorithm is expected to be implemented as workflow enhancement for transthoracic clinical applications on EPIQ and Affiniti Ultrasound Systems in the VM13 software release. The Auto-Measure and AutoStrain features, cleared on Philips EPIQ and Affiniti systems (K211597, K190913 resp.) support users during B-mode (2D), CW-, PW- and TDI-Doppler measurements by automating some of the measurements needed to complete a routine transthoracic echo (TTE) exam for adult patients. The current AutoMeasure and AutoStrain applications require input from physio signal (ECG), using electrodes, because the modules and their detectors work on single cardiac cycles, starting and ending with the End Diastole (ED), or more precisely, with delimiting R-trigger events as a good approximation. Determining the R-triggers is currently done on the EPIQ and Affiniti Ultrasound Systems by a dedicated physio board. To enable clinical users to be able to use AutoMeasure and AutoStrain application without the R-trigger (ECG based) input, R-trigger feature (non-ECG-based) has been developed.
- Expected benefits
- Accelerate ultrasound workflows: the R-trigger algorithm is expected to be implemented as workflow enhancement for transthoracic clinical applications on EPIQ and Affiniti Ultrasound Systems in the VM13 software release. The Auto-Measure and AutoStrain features, cleared on Philips EPIQ and Affiniti systems (K211597, K190913 resp.) support users during B-mode (2D), CW-, PW- and TDI-Doppler measurements by automating some of the measurements needed to complete a routine transthoracic echo (TTE) exam for adult patients.
- What the system outputs
- Automates some routine ultrasound measurements. The intended use of EPIQ Ultrasound Diagnostic System is diagnostic ultrasound imaging and fluid flow analysis of the human body, with the following indications for use: Abdominal, Cardiac Adult, Cardiac other (Fetal), Cardiac Pediatric, Cerebral Vascular, Cephalic (Adult), Cephalic (Neonatal), Fetal/Obstetric, Gynecological, Intraoperative (Vascular), Intraoperative (Cardiac), intra-luminal, intra-cardiac echo, Musculoskeletal (Conventional), Musculoskeletal (Superficial), Ophthalmic, Other: Urology, Pediatric, Peripheral Vessel, Small Organ (Breast, Thyroid, Testicle), Transesophageal (Cardiac), Transrectal, Transvaginal, Lung. Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, and Harmonic Imaging.
- How it was built or bought
- Vendor Purchased
- Custom-developed code
- No
Left blank in the record: Justification given, Operational or pilot start, Vendors, Authorization to Operate, System name, Data used to train, tune or evaluate, Federal Data Catalog link, Uses personally identifiable information, Privacy Impact Assessment, Demographic features used, Public source code, Pre-deployment testing, Impact assessment completed, Potential impacts identified, Independent review, Ongoing monitoring, Operator training, Fail-safe, Appeal process, Consultation with users and the public. Point of contact details are in the source file.
Source
Source: row 3482 of 2025_individually_reported_AI_use_cases.csv in OMB's 2025 Federal Agency AI Use Case Inventory repository (summary as of April 13, 2026), read Nov 17, 2026. File SHA-256 a62721202ca4b110
Life areas: Health and medicine, Veterans.
Records, not ratings. Every entry is what an agency reported to OMB, quoted as filed. The register does not test, rate or vouch for any system, and a record does not prove how a system is used day to day.
Other high impact cases at the VA
- Employee Transactions for HR Decision-Making Pre-deployment
- Automated Claims Processing Deployed
- Cyber Authorization Memo Generation Pre-deployment
- Clinical AI Agent Pre-deployment
- Lexis+ Pre-deployment
- VA VoiceBot for Call Center Modernization Pre-deployment
- Forescout: AI Behavioral Anomaly Detection w/ Automated Enforcement Pre-deployment
- VA AI Assist Pre-deployment
- Service Period Validator (SPV) POC Pre-deployment
- Claims Processing Automation Quality Auditor POC Pre-deployment
- CSOC AI Analyst Accelerator (Andesite AI) Pre-deployment
- Exam Verification Agent Pre-deployment
