# Velacur | VA High Impact SI

> Department of Veterans Affairs: "Velacur", a high impact SI use case at the deployed stage, quoted from the 2025 federal inventory. Sourced and dated.

Source: https://tsio.si/gov-register/case/va-24-4279/
Updated: 2026-11-19
Publisher: The SI Observatory (tsio.si), run by the SI community, built by Codeflex

1. [Home](https://tsio.si/)
2. [Government SI Register](https://tsio.si/gov-register/)
3. [Department of Veterans Affairs](https://tsio.si/gov-register/va/)
4. Velacur

Government SI Register · VA · High impact

# Velacur

**The Department of Veterans Affairs lists "Velacur" in the 2025 federal inventory as a high impact SI use case at the deployed stage, in VHA: Veterans Health Administration.** In the agency's words, the problem it is meant to solve: "Velacur is a portable device intended to measure the stiffness and attenuation of the liver in a non-invasive way, via measurement of liver tissue shear modulus and ultrasound attenuation. This is done by measuring the wavelength or wave speed of mechanically created shear aves within the organ of the patient. Attenuation is measured directly via the loss in power of the ultrasound beam. The device is designed to be ..." Every field below is quoted as filed.

ID **VA-24-4279** · Stage **Deployed** · Source row **3475**

The full record

[All VA use cases](https://tsio.si/gov-register/va/)

The record, as filed

## Every field the agency reported

- **Bureau or component**: VHA: Veterans Health Administration
- **Stage**: Deployed
- **High impact status**: High-impact
- **Topic area**: Health and Medical
- **Technology type**: Classical ML
- **Problem it is meant to solve**: Velacur is a portable device intended to measure the stiffness and attenuation of the liver in a non-invasive way, via measurement of liver tissue shear modulus and ultrasound attenuation. This is done by measuring the wavelength or wave speed of mechanically created shear aves within the organ of the patient. Attenuation is measured directly via the loss in power of the ultrasound beam. The device is designed to be used at the point of care, in clinics and hospitals. The device is used by a medical professional, an employee of the clinic/hospital. The activation unit is placed under the patient, while lying supine on an exam bed. The activation unit vibrates at frequencies of 40, 50, and 60 Hz, causing shear waves within the liver of the patient. The ultrasound transducer is placed on the patient’s skin, over the intercostal space, and is used to take volumetric scans of the liver while shear waves are occurring. The device includes two algorithms designed to help users detect good quality shear waves and identify liver tissue. From the scan data, the device calculates tissue stiffness and attenuation. Minor hardware and software changes were made to the device. The organ guide (cleared in K223287) was also extended to add more optional overlays on top of the liver overlay to help with optimizing the scan and training users to obtain adequate images. The significant change is the addition of a new output measure for Velacur, an ultrasound derived fat fraction (VDFF).
- **Expected benefits**: Support liver stiffness measurements.
- **What the system outputs**: The Velacur Determined Fat Fraction combines ultrasound attenuation and backscatter coefficient measurements. The device is indicated to determine liver tissue stiffness, attenuation, and Velacur Determined Fat Fraction in a non-invasive way. VDFF is not intended to be used in pediatric patients. This device's outputs are meant to be used in conjunction with other clinical indicators in order to aid in clinical management of patients with liver diseases, including hepatic steatosis. The device is intended to be used in a clinical setting and by trained medical professionals.
- **How it was built or bought**: Vendor Purchased
- **Custom-developed code**: No

Left blank in the record: Justification given, Operational or pilot start, Vendors, Authorization to Operate, System name, Data used to train, tune or evaluate, Federal Data Catalog link, Uses personally identifiable information, Privacy Impact Assessment, Demographic features used, Public source code, Pre-deployment testing, Impact assessment completed, Potential impacts identified, Independent review, Ongoing monitoring, Operator training, Fail-safe, Appeal process, Consultation with users and the public. Point of contact details are in the source file.

Source

Source: row 3475 of [2025_individually_reported_AI_use_cases.csv](https://github.com/ombegov/2025-Federal-Agency-AI-Use-Case-Inventory/blob/main/Data/2025_individually_reported_AI_use_cases.csv) in OMB's [2025 Federal Agency AI Use Case Inventory](https://github.com/ombegov/2025-Federal-Agency-AI-Use-Case-Inventory) repository (summary as of April 13, 2026), read Nov 17, 2026. File SHA-256 `a62721202ca4b110`

Life areas: [Health and medicine](https://tsio.si/gov-register/area/health/), [Veterans](https://tsio.si/gov-register/area/veterans/).

**Records, not ratings.** Every entry is what an agency reported to OMB, quoted as filed. The register does not test, rate or vouch for any system, and a record does not prove how a system is used day to day.

Other high impact cases at the VA

- [Employee Transactions for HR Decision-Making](https://tsio.si/gov-register/case/va-25-897/) Pre-deployment
- [Automated Claims Processing](https://tsio.si/gov-register/case/va-24-1938/) Deployed
- [Cyber Authorization Memo Generation](https://tsio.si/gov-register/case/va-25-6956/) Pre-deployment
- [Clinical AI Agent](https://tsio.si/gov-register/case/va-25-7168/) Pre-deployment
- [Lexis+](https://tsio.si/gov-register/case/va-25-2455/) Pre-deployment
- [VA VoiceBot for Call Center Modernization](https://tsio.si/gov-register/case/va-24-2758/) Pre-deployment
- [Forescout: AI Behavioral Anomaly Detection w/ Automated Enforcement](https://tsio.si/gov-register/case/va-24-585/) Pre-deployment
- [VA AI Assist](https://tsio.si/gov-register/case/va-25-1294/) Pre-deployment
- [Service Period Validator (SPV) POC](https://tsio.si/gov-register/case/va-25-1877/) Pre-deployment
- [Claims Processing Automation Quality Auditor POC](https://tsio.si/gov-register/case/va-25-1930/) Pre-deployment
- [CSOC AI Analyst Accelerator (Andesite AI)](https://tsio.si/gov-register/case/va-25-3685/) Pre-deployment
- [Exam Verification Agent](https://tsio.si/gov-register/case/va-25-3767/) Pre-deployment